How alternating current is generated
Step the generator forward by a quarter turn. At the neutral plane, the magnetic flux has its greatest magnitude and the induced EMF is zero. A quarter turn later the flux is zero and the EMF is at a peak. A transformer also relies on changing flux, which is why a steady DC supply gives zero secondary voltage.
From a rotating coil to alternating current
The generator turns a rectangular coil ABCD at constant speed about an axis perpendicular to a uniform magnetic field. As sides AB and CD move across the field, an electromotive force (EMF) is induced. The ends of the coil connect to two copper slip rings K and L that turn with it. Stationary brushes carry the current from the rings to the external circuit.
Side AB moves across the field in opposite directions on successive half-turns. The current reverses and the center-zero galvanometer deflects to alternate sides. The generator converts mechanical energy into electrical energy.
Flux and EMF are a quarter cycle apart
At the neutral plane, the coil is perpendicular to the field and the magnitude of the flux Φ through it is greatest. At that instant, sides AB and CD travel along the field lines, the rate of change of flux is zero, and e = 0. The current reverses at each neutral-plane crossing, twice per turn.
When the coil is parallel to the field, no field lines pass through it and Φ = 0. Sides AB and CD move across the field at right angles, so flux changes fastest and |e| reaches its peak. Compare the two graphs to see the quarter-cycle shift.
Instantaneous, peak and RMS values
Let the coil have N turns, area S and angular speed ω. Starting at the neutral plane gives θ = ωt and flux through one turn Φ = BS cos ωt. By Faraday’s law, e = Em sin ωt, where Em = NBSω. Starting a quarter turn later gives e = Em cos ωt. In the resistive circuit, the current is i = e/(R + r) and the load voltage is u = iR.
The period T is the time for one cycle, and the frequency f is the number of cycles per second. T = 1/f and ω = 2πf. At 50 Hz, each cycle lasts 0.02 s and the current reverses 100 times per second.
The root-mean-square value (RMS) of an alternating current is the steady current that would release the same heat in the same resistor over a whole number of cycles. For a sine wave, E = Em/√2, U = Um/√2 and I = Im/√2. RMS is used for AC meter readings, appliance ratings and resistive power calculations. Peak voltage matters when checking whether a capacitor’s insulation can break down.
Slip rings and the commutator
Slip rings carry the alternating coil current directly to the external circuit. A split-ring commutator swaps the coil ends connected to the two brushes on every neutral-plane crossing. The coil current still alternates, while the external current always flows in the same direction when it flows. Its magnitude varies, producing pulsating DC.
How transformers change AC voltage
The primary coil connects to the supply and the secondary coil connects to the load. The primary produces a changing flux in the closed iron core. The same flux passes through the secondary and induces an EMF by mutual induction. In the ideal transformer, each turn links the same changing flux, so U₁/U₂ = n₁/n₂.
An ideal transformer has no energy losses, so P₁ = P₂. With one secondary and the resistive load in this model, U₁I₁ = U₂I₂ and I₁/I₂ = n₂/n₁ when current flows. More secondary turns step the voltage up, while fewer step it down. The input voltage and turns ratio set U₂. The load and U₂ set I₂, and output power determines input power. Opening the load switch makes both ideal currents zero while U₂ remains. With steady DC, the magnetic flux is constant and the secondary voltage is zero.
Summary of relationships
| Position or quantity | Magnetic flux Φ | Induced EMF e | Notes |
|---|---|---|---|
| Neutral plane (coil ⊥ B) | |Φ| = BS | 0 | Coil current reverses as it crosses the plane. |
| Coil ∥ B | 0 | |e| = Em = NBSω | Sides AB and CD move across the field at right angles. |
| Start at neutral plane | Φ = BS cos ωt | e = Em sin ωt | Starting a quarter turn later gives e = Em cos ωt. |
| RMS | E = Em/√2 for a sine wave. Use RMS for meter readings, ratings and resistive heating. | ||
| Ideal transformer | U₁/U₂ = n₁/n₂, I₁/I₂ = n₂/n₁, P₁ = P₂. Frequency stays the same. Steady DC gives zero secondary voltage. | ||
Try it in the simulation
- In AC generator, select “Step T/4”. Compare the end view and graphs at each stop. Where does |Φ| peak while e is zero?
- Watch the gold current markers on side AB. Count how many times the current reverses in one full turn.
- Increase turns N, field B and rotation rate n one at a time. Compare their effects on Em. Which slider also changes the period and frequency?
- Set the start position to “Coil ∥ field”. The EMF starts at a peak and the expression changes from sine to cosine.
- Select “Commutator (DC)”. The coil current still reverses, and the galvanometer in the external circuit deflects to one side of zero.
- In Transformer, try the different turns ratios and compare U₂, I₁ and I₂. Open the load and check I₁ and U₂. Then select “Use DC” and check the lamp and U₂.
Frequently asked questions
How does an AC generator produce alternating current?
Rotate a rectangular coil at constant speed about an axis perpendicular to a uniform magnetic field. As sides AB and CD move across the field, an EMF is induced. The EMF changes magnitude and sign over every turn, so a closed circuit carries alternating current. The generator converts mechanical energy into electrical energy and sends current to the circuit through two slip rings and brushes.
What is the neutral plane of a generator coil?
At the neutral plane the coil is perpendicular to the field, so the magnitude of flux is greatest. Sides AB and CD move along the field. Flux is momentarily steady, the induced EMF is zero, and current reverses as the coil crosses the plane. This happens twice per turn. When the coil is parallel to the field, flux is zero and the EMF reaches its peak magnitude.
How do you write the instantaneous EMF of an AC generator?
First find the peak Em = NBSω, with N the number of turns, S the coil area and ω = 2πn the angular speed. Starting at the neutral plane gives e = Em sin ωt. Starting a quarter turn later with the coil parallel to the field gives e = Em cos ωt. For an axis in the plane of the coil and perpendicular to the field, the peak depends on coil area. The current is i = e/(R + r) and the load voltage is u = iR.
What is RMS and how is it related to the peak value?
The RMS current is the steady current that produces the same heat in the same resistor over a whole number of cycles. For a sine wave, E = Em/√2, U = Um/√2 and I = Im/√2. AC supply ratings and typical AC meters use RMS values. A 220 V RMS sine wave has a peak of about 311 V.
How does a transformer work, and what happens with DC?
A transformer has primary and secondary coils wound around a closed iron core. A changing current in the primary changes the flux that links both coils and induces EMF in the secondary. This is mutual induction. With steady DC the flux is constant and the secondary EMF is zero. A change in current at switch-on or switch-off can briefly induce an EMF.
How do turns affect voltage and current in an ideal transformer?
For an ideal transformer, U₁/U₂ = n₁/n₂ and P₁ = P₂. With one secondary and a resistive load, I₁/I₂ = n₂/n₁ when current flows. More turns on the secondary step up the voltage. Fewer turns step it down. Input voltage and turns ratio set the secondary voltage. The secondary load determines the current drawn from the primary and the input power. Both sides operate at the same frequency.
For students and teachers
Use this simulation in secondary-school physics to introduce generators or practice electromagnetic induction, sinusoidal waveforms, RMS values and ideal transformers. For a classroom prediction, pause at the neutral plane and ask students to sketch the flux and EMF after one quarter turn. Then step the coil and compare their sketches with the graphs.